RING COMPRESSOR RB-60

1. Casing is made of aluminum alloy and have excellent features on mechanic strength , durability , light weight and smooth exterior.
2. Impeller is made of aluminum alloy and have excellent features on mechanic strength , durability , and light weight.
3. RB series ring compressors are designed to comply with the safety requirements of CE / cCSAus and have attained their type approval.
4. Design per customers requirement available.
5. Thermal protector is optional.

 

 

Meet CE Norm 89/336 , 73/23 , EN60204-1 , EN50081-2 , EN50082-2
Degree of protection IP 54 (IP 55 optional)
Insulation class F class (155 degrees centigrade)

Voltage range /

Frequency

A 50Hz 500 V
60Hz 575 V
B 50Hz 200 ~ 240 / 345 ~ 416 V
60Hz 208 ~ 275 / 380 ~ 480 V
C 50Hz 400 / 690
60Hz 460 / ---
D 50Hz 1 phase 230V +- 5%
60Hz ---
Installation Any aspect.

 

 

 
Specification and Operation Diagram

 

Blowers with 50 Hz
Model Phase

Voltage

Hz


kW

Rated Current
Amps (*1)

Max.
Pressure
mbar(*2)

Max.
Airflow
m3/min

Noise
Level
dB(A) (*3)

Weight
kg

RB60-5B0 3 200 ~ 240 / 345 ~ 416 50 2.20 10.8~10.9 / 6.0~6.1 +220 5.1 76 36
RB60-5B0-9 2.20 9.0~9.9 / 5.3~5.8 +200 36
RB60-6B0 3.00 13.1~13.6 / 7.4~7.7 +280 38.4
RB60-7B0 4.00 14.7~14.8 / 8.5~8.4 +340 41.5
RB60-5D0 1 230 2.20 14.9 +200 42

 

Blowers with 60 Hz
Model Phase

Voltage

Hz


kW

Rated Current
Amps (*1)

Max.
Pressure
mbar(*2)

Max.
Airflow
m3/min

Noise
Level
dB(A) (*3)

Weight
kg

RB60-5B0 3 208 ~ 275 / 380 ~ 480 60 2.55 11.3~10.6 / 6.4~5.9 +200 6.2 78 36
RB60-5B0-9 2.55 12.2~10.9 / 6.6~6.2 +255 36
RB60-6B0 3.45 14.9~13.2 / 8.0~7.6 +270 38.4
RB60-7B0 4.60 17.2~14.7 / 9.5~8.5 +330 41.5

Remark 1. under condition (*2) , the test value.

Remark 2. Max. pressure for continuous operation permitted.

Remark 3. dB(A) value gets from 4 points & 1 meter distance test.

Remark 4. can not be operated with closed intake & outlet , a suitable pressure-relief valve must be used.


     

 

Vacuum with 50 Hz
Model Phase

Voltage

Hz


kW

Rated Current
Amps (*1)

Max.
Pressure
mbar(*2)

Max.
Airflow
m3/min

Noise
Level
dB(A) (*3)

Weight
kg

RB60-5B0 3 200 ~ 240 / 345 ~ 416 50 2.20 11.6~9.9 / 5.6~5.8 -230 5.1 76 36
RB60-5B0-9 2.20 8.0~9.4 / 4.5~5.3 -180 36
RB60-6B0 3.00 11.1~12.4 / 6.3~7.0 -250 38.4
RB60-7B0 4.00 11.5~12.5 / 6.7~7.2 -270 41.5
RB60-5D0 1 230 2.20 14.7 -200 42

 

Vacuum with 60 Hz
Model Phase

Voltage

Hz


kW

Rated Current
Amps (*1)

Max.
Pressure
mbar(*2)

Max.
Airflow
m3/min

Noise
Level
dB(A) (*3)

Weight
kg

RB60-5B0 3 208 ~ 275 / 380 ~ 480 60 2.55 11.2~10.1 / 6.0~5.7 -220 6.2 78 36
RB60-5B0-9 2.55 10.2~9.8 / 5.6~5.5 -230 36
RB60-6B0 3.45 13.2~12.3 / 7.1~7.0 -270 38.4
RB60-7B0 4.60 15.3~13.2 / 8.2~7.7 -320 41.5

Remark 1. under condition (*2) , the test value.

Remark 2. Max. pressure for continuous operation permitted.

Remark 3. dB(A) value gets from 4 points & 1 meter distance test.

Remark 4. can not be operated with closed intake & outlet , a suitable pressure-relief valve must be used.


     
 
 
Dimensions

 

RB-60-5B , RB-60-6B

     

 

RB-60-7B , RB-60-5D