Ring Compresser RB-40 

1. Casing is made of aluminum alloy and have excellent features on mechanic strength , durability , light weight and smooth exterior.
2. Impeller is made of aluminum alloy and have excellent features on mechanic strength , durability , and light weight.
3. RB series ring compressors are designed to comply with the safety requirements of CE / cCSAus and have attained their type approval.
4. Design per customers requirement available.
5. Thermal protector is optional.

 

 

Meet CE Norm 89/336,73/23,EN60204-1,EN50081-2,EN50082-2
Degree of protection IP 54 (IP 55 optional)
Insulation class F class (155 degrees centigrade)

Voltage range /

 Frequency

A 50Hz 500 V
60Hz 575 V
B 50Hz 200 ~ 240 / 345 ~ 416 V
60Hz 208 ~ 275 / 380 ~ 480 V
C 50Hz 400 / 690
60Hz 460 / ---
2 50Hz 200 ~ 240 / 380 ~ 440 V
60Hz
1 50Hz 1 Phase  100 ~ 120 / 200 ~ 240 V
60Hz
9 50Hz 1 Phase  104 ~ 127 / 208 ~ 254 V
60Hz 1 Phase  104 ~ 127 / 208 ~ 254 V
Installation Any aspect.
 
Specification and Operation Diagram

 

 Blowers with 50 Hz
Model Phase

Voltage

Hz

kW

Rated Current Amps (*1)

Max. Pressure mbar(*2)

Max. Airflow m3/min

Noise Level
dB(A)
(*3)

Weight kg

RB40-4B0 3 200 ~ 240 /
345 ~ 416
50 0.76 3.6~4.85 /
2.0~2.65
+140 2.4 69 15.3
RB40-4B0-9 0.76 3.53~4.74 / 2.0~2.63 +155 15.3
RB40-4B0-F 0.76 2.98~4.67 / 1.68~2.5 +100 15.3
RB40-5B0 0.90 4.3~4.8 /
2.5~2.82
+180 16.0
RB40-6B0 1.10 4.8~5.53 / 2.77~3.14 +200 17.2
RB40-590 1 104~127 / 208~254 0.80 11.3~14.6 /
5.7~7.4
+150 17.0
RB40-690 1.10 14.5~16.4 /
7.2~8.3
+190 18.2

 

 Blowers with 60 Hz
Model Phase

Voltage

Hz

kW

Rated Current Amps (*1)

Max.
Pressure
mbar(*2)

Max.
Airflow
m3/min

Noise
Level

dB(A)
(*3)

Weight kg

RB40-4B0 3 208 ~ 275 /
380 ~ 480
60 0.93 3.48~4.16 / 1.95~2.34 +135 3.0 72 15.3
RB40-4B0-9 0.93 4.4~4.58 /
2.42~2.63
+170 15.3
RB40-4B0-F 0.93 3.48~4.16 / 1.95~2.34 +135 15.3
RB40-5B0 1.15 4.87~4.6 /
2.63~2.74
+180 16.0
RB40-6B0 1.50 6.0~5.5 /
3.3~3.25
+230 17.2
RB40-590 1 104~127 / 208~254 0.90 15.1~12.2 /
7.6~6.2
+160 17.0
RB40-690 1.30 16.4~13.3 /
8.1~6.7
+180 18.2

Remark 1. under condition (*2) , the test value.

Remark 2. Max. pressure for continuous operation permitted.

Remark 3. dB(A) value gets from 4 points & 1 meter distance test.

Remark 4. can not be operated with closed intake & outlet , a suitable pressure-relief valve must be used.


     

 

 Vacuum with 50 Hz
Model Phase

Voltage

Hz

kW

Rated Current Amps (*1)

Max.
Pressure
mbar
(*2)

Max.
Airflow
m3/min

Noise Level
dB(A)
(*3)

Weight kg

RB40-4B0 3 200 ~ 240 /
345 ~ 416
50 0.76 3.51~4.78 /
2.02~2.63
-140 2.4 69 15.3
RB40-4B0-9 0.76 3.34~4.63 /
1.9~2.59
-130 15.3
RB40-4B0-F 0.76 2.86~4.51 /
1.6~2.48
-90 15.3
RB40-5B0 0.90 4.0~4.66 /
2.31~2.74
-170 16.0
RB40-6B0 1.10 4.5~5.35 /
2.54~3.05
-180 17.2
RB40-590 1 104~127 /
208~254
0.80 11.68~14.45 / 5.82~7.39 -155 17.0
RB40-690 1.10 13.2~16.0 /
6.59~8.12
-170 18.2

 

 Vacuum with 60 Hz
Model Phase Voltage

Hz

kW

Rated Current Amps (*1)

Max.
Pressure
mbar
(*2)

Max.
Airflow
m3/min

Noise Level
dB(A)
(*3)

Weight kg

RB40-4B0 3 208 ~ 275 /
380 ~ 480
60 0.93 3.7~4.37 /
2.08~2.47
-135 3.0 72 15.3
RB40-4B0-9 0.93 4.0~4.45 /
2.24~2.53
-165 15.3
RB40-4B0-F 0.93 3.18~3.98 / 1.83~2.35 -120 15.3
RB40-5B0 1.15 4.65~4.65 / 2.61~2.71 -180 16.0
RB40-6B0 1.50 5.49~5.27 /
3.0~3.15
-210 17.2
RB40-590 1 104~127 / 208~254 0.90 14.48~11.8 / 7.25~6.0 -165 17.0
RB40-690 1.30 16.15~13.06 / 8.04~6.54 -180 18.2

Remark 1. under condition (*2) , the test value.

Remark 2. Max. pressure for continuous operation permitted.

Remark 3. dB(A) value gets from 4 points & 1 meter distance test.

Remark 4. can not be operated with closed intake & outlet , a suitable pressure-relief valve must be used.


     

 
 
Dimensions

 